login english language greek language

 

Evolved Gas Analysis - QMS (EGA)

 Mass spectrometry (MS) is an analytical technique to measure the mass of atoms or molecules of a gas e.g. evaporated from a sample material which has been heated up. The spectra are used to determine the elemental or isotopic signature of a sample, the masses of particles and of molecules, and to elucidate the chemical structures of molecules, such as peptides and other chemical compounds. Mass spectrometry works by ionizing chemical compounds to generate charged molecules or molecule fragments and measuring their mass-to-charge ratios.

The QMS - quadrupole mass spectrometer coupling device is a state of the art mass spectrometer with a heated inlet system. The QMS is used for the analysis of volatile decompositions. All Linseis instrumentsare especially designed to guarantee a user friendly operation of both the Thermal Analyzer and the Mass Spectrometer. A integrated Software solution is certainly available.

Example System: Coupling Thermo Balance TG/STA + Quadrupol Mass-spec(QMS):

Both manufacturers Linseis and Pfeiffer are some of the leading companies in their specialized fields. This cooperation guarantees outstanding performance for the combined system.

  • Transfer line is temperature controlled up to a maximum of 250°C.
  • Fast response time through short transfer line.
  • MS detector with very high sensitivity and with different mass numbers available.

The following applications can be measured:

  • Outgasing components of burned material (paints etc.)
  • Determination of blenders and additives.
  • Absorption and Desorption processes.
  • Analysis of rubbers and plastics.

Features

  • Linseis Research balance (different models) with TG or simultaneous TG/DSC or TG/DTA measurement.
  • Simultaneous balance with (0.1/0.5/1µg) resolution and 25gram max. sample weight.
  • Specific heat measurements (Cp) possible.
  • Pfeiffer/Balzers mass spectrometer model Thermostar (0 - 100 amu, 0 - 200 amu, 0 - 300 amu)
  • Highest precision Quattropol-MS from world leader in MS Technology.
  • MS with very compact dimensions.
  • Very easily exchangeable quartz capillary.
  • Three separate heating zones, at capillary, at TG protection tube and at MS vacuum inlet.
  • Carrier gas with wide range of flow rates.
  • Especially developed Al2O3 "sniffer-nose", to extract the out gases.
  • Combined results of TG and MS available in one evaluation sheet.
  • Complete vacuum tight system.
 

Specifications:

Massnumbers:100/200/300 amu
Detector:Faraday and SEV (Channeltron)
Ion source:Electron impact, Energy: 100 eV
Vacuum system:Turbomolecular and Diaphragm pump (oil free)
Heating: Adapter, heated capillary and QMS
Couplings:DSC, TGA, STA, DIL by heated capillary
 

Accessories:

Pulse-Analysis

The Pulse-Analysis injects a exactly predetermined amount of liquid or gas into the Thermobalance (TGA) or Simultaneous Thermal Analyzer (STA). This enhances the measurement possibilities significantly: the MS or FTIR can now be calibrated. Out gassings can be quantified precisely with this method.

 
 Contact us for more details
 Επιστροφή
Κεντρικά: Σταματίου Ψάλτου 30, 54644 Θεσσαλονίκη, Τηλ.: (+30) 2310-855844, Φαξ: (+30) 2310-886206
Υποκατάστημα: Μομφεράτου 131, 11475 Αθήνα, Τηλ.: (+30) 210-6452848, Φαξ: (+30) 210-6452413, www.megalab.gr, contact@megalab.gr

Created Alpha