login english language greek language

 

ΑΡΧΙΚΗ \ ΠΡΟΪΟΝΤΑ \ Αναλυτικός Εξοπλισμός \ Linseis \ Laser Flash / Xenon Flash Analyzer (LFA)

THB - Transient Hot Bridge - Thermal Conductivity Meter

Transient Hot Bridge - Thermal Conductivity Meter

 

The Linseis Transient Hot Bridge - Thermal Conductivity Meter enables thermal conductivity, thermal diffusivity and specific heat measurements on various sample geometries and materials. This Linseis measuring instrument provides the three material properties simultaneously after just a few minutes time regardless of whether you have used the patented sensor in a solid matter (incl. bulk material, gels, pastes) or in a liquid. The preparation of solid samples is pretty simple: One pla-ne surface of two sample halves is sufficient for the sensor. Reference or calibration measurements are a thing of the past. As a matter of course, the THB measures absolute values, with an uncertainty which is not behind that of conventional plate or our laser flash devices.

Different sensors, easily to be exchanged, are available for laboratory and field use. The THB measures fully automatically. Its software control optimizes the measurement process independently, aiming at a short duration and a minimum uncertainty.

Advantages:

  • Highest Accuracy
  • Absolute technique (no calibration or reference sample required)
  • Fast measurement cycles
  • Non destructive measurement
  • Broad measuring range
  • Broad temperature range
  • Easy handling (no trained staff required)
  • Simple sample preparation
  • Applicable for solids, liquids, powders and pastes
  • No influence of sensor contact pressure on measurement
  • Easy measurement of porous and transparent samples


 
Specifications:
Model:THB 1THB 100THB 500
Measuring ranges
Thermal conductivity:0.01 up to 1 W/(mK) 0.01 up to 100 W/(mK) 0.01 up to 500 W/(mK)
Thermal diffusivity:0.05 up to 10 mm2/s0.05 up to 10 mm2/s0.05 up to 10 mm2/s
Specific thermal capacity: 100 to 5000 kJ/(m3 K)100 to 5000 kJ/(m3 K)100 to 5000 kJ/(m3 K)
Measurement uncertainties  
Thermal Conductivity: better than 2 % better than 2 % better than 2 %
Thermal Diffusivity: better than 5 %better than 5 %better than 5 %
Heat Capacity: better than 5 %better than 5 %better than 5 %
Duration of the measurement
Solids:typically 1 to 10 mintypically 1 to 10 mintypically 1 to 10 min
Liquids:typically 1 to 120 stypically 1 to 120 stypically 1 to 120 s
Service temperature 
Sensor:–150 °C to 200 °C –150 °C to 200 °C or -150 to 600°C  –150 °C to 200 °C or -150 to 600°C  
Sensor type:Kapton insulated sensor Kapton or Ceramic insulated sensor Kapton or Ceramic insulated sensor 
Sample size
Smallest sample:40 x 20 x 3 mm 3 x 3 x 3 mm  3 x 3 x 3 mm 
Maximum Sample size:unlimitedunlimitedunlimited
Sample consistence:solid, liquid, gel, powder, granulatesolid, liquid, gel, powder, granulatesolid, liquid, gel, powder, granulate
Sample temperature*: -150 up to 200 °C  -150 up to 600 °C -150 up to 600 °C

 * Optional climate chamber 

Software:

All thermo analytical devices of LINSEIS are PC controlled and the individual software modules exclusively run under Microsoft Windows operating systems. The complete software consists of 3 modules: temperature control, data acquisition and data evaluation. The Linseis 32 – bit software encounters all essential features for measurement preparation, execution and evaluation with a THB run, just like with other thermo analytical experiments. Due to our specialists and application experts LINSEISwas able to develop this easy understandable and highly practical software.

General Features

  • Repetition measurements with minimum parameter input
  • Evaluation of current measurement
  • Curve comparison up to 32 curves
  • Curve subtraction
  • Zoom function
  • Multiple smoothing functions
  • Storage and export of evaluations
  • Program capable of text editing
  • Export and import of data ASCII
  • Data export to MS Excel
  • Signal-steered measuring procedures
  • Zoom in function
  • Undo function
 

Applications:

Materials

Polymers, Organics, Metals / Alloys

Industries

Automotive / Aviation / Aerospace, Power Generation / Energy, Research, Development and Academia, Cosmetics, Pharmaceuticals and Food Industry, Chemical, Electronics Industry

Ceramic filled Polymers

In the following diagram you can see a typical measurment of a ceramic filled polymer. All three parameters, thermal Diffusivity, thermal conductivity and specific heat have been calculated and reported simultaneously. In addition to the measurement values, the Software calculates and displays the associated measurement uncertainties in accordance with the international ISO standard.

   

 

Watch the Linseis THB - Thermal Conductivity Analyzer - NEW Application Example Polymers "PMMA"

 

Watch the Linseis THB - Thermal Conductivity Analyzer - Application Example Building Materials

 

 Accessories:

Different Accessories are available for the Linseis THB:

  • Huge amount of Sensor types for many different applications. For example: 
    • Small samples, large samples
    • Liquids
    • Pastes
    • Gels
    • Solids
  • Different climate chambers for temperature range from –50 °C to 200 °C or -100 to 600°C  

 Contact us for more details
 
 Επιστροφή
Κεντρικά: Σταματίου Ψάλτου 30, 54644 Θεσσαλονίκη, Τηλ.: (+30) 2310-855844, Φαξ: (+30) 2310-886206
Υποκατάστημα: Μομφεράτου 131, 11475 Αθήνα, Τηλ.: (+30) 210-6452848, Φαξ: (+30) 210-6452413, www.megalab.gr, contact@megalab.gr