login english language greek language

 

Model 7124 - Dual Phase Lock-in Amplifier


 

 

 

  • No digital clock or switching noise present at the RCU connectors
  • 0.5 Hz to 150 kHz operating frequency range
  • Voltage and current mode inputs
  • 1.0 MHz main ADC sampling rate
  • 10 µs to 100 ks output filter time constants
  • Dual Reference, Dual Harmonic and Virtual Reference operating modes
  • USB, RS232, and Ethernet computer interfaces

Since their invention back n the 1960's, lock-in amplifiers have been used whenever the need arises to measure the amplitude and/or phase of a signal of known frequency in the presence of noise. 

 Contact us for more details 

Model 7270 - Dual Phase Lock-in Amplifier

7270

 

 

 

  • 1 mHz to 250 kHz operating frequency range
  • 1.0 MHz main ADC sampling rate
  • 10 µs to 100 ks output filter time constants
  • Dual Reference, Dual Harmonic and Virtual Reference operating Modes
  • Internal data buffer for recording instrument outputs at rates down to 1 µs per point
  • USB, RS232, and Ethernet computer interfaces

The model 7270 sets a new standard for general-purpose DSP lock-in amplifiers.

 Contact us for more details 

Model 7230 - Dual Phase Lock-in Amplifier

7230

 

  • 1 mHz to 120 kHz (250 kHz with 7230/99 option) operating frequency range
  • 1.0 MHz main ADC sampling rate
  • 10 µs to 100 ks output filter time constants
  • Dual Reference, Dual Harmonic and Virtual Reference operating Modes
  • Internal data buffer for recording instrument outputs at rates down to 1 µs per point
  • Ethernet, USB, and RS232 computer Interfaces
  • Free LabVIEW driver

The model 7230 is a new concept in general-purpose DSP lock-in amplifiers.

  Contact us for more details 

Model 7280 - Dual Phase Wide Bandwidth DSP Lock-in Amplifier

7280

 

  • 0.5 Hz to 2 MHz operation
  • Direct digital demodulation without down conversion
  • 7.5 MHz main ADC sampling Rate
  • 1 µs to 100 ks output time Constants
  • Dual Reference, Dual Harmonic and Virtual Reference modes
  • Spectral display mode
  • Scanned probe microscopy
  • Optical measurements
  • Audio studies
  • AC impedance studies
  • Atomic force micorscopy
The model 7280 DSP lock-in amplifier is an exceptionally versatile instrument with outstanding performance.

  Contact us for more details

Model 7265 - Dual Phase DSP Lock-in Amplifier

 7265

 

  • 1m Hz to 250 kHz operation
  • Direct digital demodulation without down-conversion
  • 10 µs to 100 ks output time constants
  • Synchronous oscillator output for input offset reduction
  • Dual Reference, Dual Harmonic and Virtual Reference modes
  • Spectral display mode
  • Scanned probe microscopy
  • Optical measurements
  • Audio studies
  • AC impedance studies
  • Atomic force microscopy

The SIGNAL RECOVERY model 7265 uses the latest digital signal processing (DSP) technology to extend the operating capabilities of the lock-in amplifier to provide the researcher with a very versatile unit suitable both for measurement and control of experiments.

 Contact us for more details 

Model 7225 - Dual Phase DSP Lock-in Amplifier

 7225

 

  • 1m Hz to 120 kHz Operation
  • Direct digital demodulation with down-conversion
  • 10 µs to 100 ks output time Constants
  • Synchronous oscillator output for input offset reduction
  • Harmonic measurements to 32f
  • Low Profile (IRU)
  • Chopped light measurements
  • AC bridge measurements
  • Audio studies
  • AC impedance studies
  • Vibration studies
  • Thermal wave detection

The SIGNAL RECOVERY model 7225 offers a cost-effective solution to the researcher needing the performance provided by DSP demodulation but not requiring the additional features or higher operating frequencies of the models 7280 and 7265.

 Contact us for more details

Model 5210 - High Performance Dual Phase Lock-in Amplifier

5210

 

  • 0.5 Hz to 120 kHz operation
  • Voltage and current mode inputs
  • Continuous full-scale sensitivity control
  • Powerful fourth-order signal channel Bandpass, Low Pass or Notch filter
  • Up to 130 dB dynamic Reserve
  • Synchronous 15-bit ADC for lower input jitter
  • Auger spectroscopy
  • Feedback control loops
  • Replication existing experimental setups

Over the past few years. the SIGNAL RECOVERY models 5209 (single-phase) and 5210 (dual-phase) have become the benchmark lock-in amplifiers against which others are judged.

 Contact us for more details

Model 5105 - Dual Phase Lock-in Amplifier

5105

 

  • 5 Hz to 20 kHz operation (or single "spot" frequency up to 100 kHz)
  • Low Cost
  • Squarewave demodulation
  • Adjusting low pass and high-pass signal channel filters
  • Up tp 80 dB dynamic Reserve
  • Chopped light measurements
  • Multiple instrument systems
 Επιστροφή
Κεντρικά: Σταματίου Ψάλτου 30, 54644 Θεσσαλονίκη, Τηλ.: (+30) 2310-855844, Φαξ: (+30) 2310-886206
Υποκατάστημα: Μομφεράτου 131, 11475 Αθήνα, Τηλ.: (+30) 210-6452848, Φαξ: (+30) 210-6452413, www.megalab.gr, contact@megalab.gr

Created Alpha