This model is effective for standard cell disruption and many other small volume applications. Probes are available in three different sizes.
Contact us for more details
The unit is effective for standard cell disruption, DNA/RNA shearing, homogenization and many other applications. The Q125 is ideal for small samples and for customers that do not plan to scale up to larger volumes in the future. This model offers the same programming and display features as the Q500 unit.
Programmable operation
Set time and amplitude for hands free operation
Pulse modePrevent heat buildup in temperature sensitive samples
Digital amplitude / intensity controlOutput intensity can be set from 20-100%
Elapsed time indicatorDisplays duration of sonication
Display of wattage and joulesReal-time energy monitoring
Overload protectionPrevents damage to circuitry if a fault occurs
RoHS compliantUses lead free components
Compact designTakes up less space than competitive units
Adjustable pulse On and Off times can be programmed from 1 second to 1 minute. Total programming has a maximum setting of 10 hours. A wide variety of probes and accessories are available to handle virtually any application.
Part #Q500 includes a standard ½” diameter probe with replaceable tip (#4220). A variety of probe/horn options are available and the system can be purchased without the standard probe by selecting #Q500A.
Programmable operationSet time and amplitude for hands free operation
The Q700 is the only sonicator on the market that offers full amplitude control from 1-100%. This enables greater control of the probe’s intensity, helping to pinpoint the optimum settings for efficient sample processing. We have increased maximum power output to 700 watts making the system more durable and capable of handling even larger samples if necessary. Our new display, design improvements and added accessories make this the most sophisticated and versatile Sonicator available today.
Part #Q700 includes a standard ½” diameter probe with replaceable tip (#4220). A variety of probe/horn options are available and the system can be purchased without the standard probe by selecting #Q700A.
Full amplitude controlAmplitude (intensity) is controlled from 1-100% giving a greater degree of resolution and the ability to pinpoint the amplitude needed to effectively process your sample.
ProgrammabilityParameters including processing times, pulse on/off and amplitude can be saved to memory and run by the touch of a button.
Pulse modeAdjustable pulse On and Off times to reduce the heat gain in temperature sensitive samples.
Temperature monitoringAn optional temperature probe is available for those customers who wish to monitor the temperature of their sample. If the temperature limit is reached, sonication shuts down to prevent overheating
RoHS compliantAll Qsonica equipment is built lead free.
Run multiple programs in sequenceMultiple programs can be run in sequence. For example, the unit can be programmed to sonicate at 50% amplitude for 5 minutes, shut off for 2 minutes and re-start at 25% amplitude for 10 minutes. Up to 5 programs can be run in succession.
Total energy output displayEnergy delivered to the probe is displayed in both Watts and Joules.
Auto tuningThe Sonicator digitally tracks frequency changes in the converter / tip assembly caused by load and temperature changes and maintains electrical efficiency at all times. Manual tuning is unnecessary.
Overload protectionThe unit is equipped with fault detection circuitry to shut down sonication in the event that a fault occurs.
Touch Screen ControlA large, color LCD screen clearly displays all operating parameters and options. Intuitively and quickly access any of the sonciator’s functions with a simple touch.
The Q800R is a complete package including a chiller to control temperature, digital operating system with programmable memory, high intensity ultrasonic horn and sound reducing enclosure.
4 tube rack options are offered to hold a variety of commercially available sample tubes from 1.5m to 300ul. Volumes as small as 50ul are easily processed. Samples are sonicated in closed vessels to prevent cross contamination and foaming. The Q800R incorporates sample rotation to ensure even sonication and reproducible results. Internal lighting illuminates the sample tubes so they can be viewed during processing.
In addition to epigenetic uses, the Q800R can be used as a high throughput sonication method for a variety of applications including cell lysis, dissolution and tissue disruption.
• High Throughput - Up to 24 samples at a time• Reproducible Results• Custom sample tubes are not required• Illuminated sample viewing window• Customized sample rack available• Two-Year Warranty
ChIP Protocols
DNA Shearing Protocols
Publications
KDM4A Lysine Demethylase Induces Site-Specific Copy Gain and Rereplication of Regions Amplified in Tumors - Joshua C. Black et al., 2013
Cell, Volume 154, Issue 3, 541-555, 18 July 2013
Enhanced in vivo Fitness of Carbapenem-resistant oprD mutants of Pseudomonas Aeruginosa Revealed Through High-throughput Sequencing
Skurnika et al., PNAS, Volume 110 No. 51, 20747–20752, 17 December 2013
Coupling Mutagenesis and Parallel Deep Sequencing to Probe Essential Residues in a Genome or Gene
Robins et al., PNAS, Volume 110 No. 9, E848–E857, 26 February 2013
The Q1375 Sonicator offers the ability to program processing times and a full range of intensity settings. Processing time can be set from 1 second to 10 hours. A pulsing feature is standard. Pulsing can reduce the amount of heat generated by sonication when processing temperature sensitive samples. A temperature monitoring probe option is also available.
Part #Q1375 includes a standard 1” diameter, 10” long probe (#4597). A variety of probe/horn options are available and the system can be purchased without the standard probe by selecting #Q1375A.
Larger, more powerful probe options are available. Contact us to discuss your high volume application.
This unit is only available in 220V line voltage. The Q1375 requires a fused, single phase 3-terminal grounding type electrical outlet capable of supplying 50/60 Hz at 220 volts, or 240 volts.
Programmable OperationSet time and amplitude for hands free operation
Pulse ModePrevent heat buildup in temperature sensitive samples
Industrial volume processingProcesses up to 40L
Temperature monitoringOptional temperature probe