CATLAB-PCS

Automated microreactor/mass

spectrometer system

SpaciMS

Spatially resolved capillary inlet

mass spectrometer

HPR-20 QIC TMS

Transient mass spectrometer for

fast event studies

TGA-MS

Mass spectrometer inlets for

connecting/coupling to TGA systems

3F-PIC

Transient mass spectrometer for

fast event UHV studies

HPR-60 MBMS

Molecular beam sampling mass

spectrometer for ion and radical analysis

 

 

Contact us for more informations   

Mass spectrometers for catalysis and thermal analysis

 

A system for catalyst characterisation, reaction testing, kinetic and

thermodynamic measurements

 

Real time gas analysis of catalyst performance
CATLAB

Temperature Range

Ambient to 1000 °C

Ramp Rate

0.1 - 20 °C/min

Reactor Pressure1 bar

Gas Streams

4 (8 optional)

Corrosive gas sampling options

Yes

Mass SpectrometerQGA (or HPR-20)
Mass Range200 or 300 amu
Concentration range100 ppm to 100 %
Gas consumption rate

16 atm cc/min (lower

flow available)

Response time from sample to

detection

500 milliseconds
Reactor size

4, 7 or 12 mm internal

diameter options

Reactor MaterialQuartz
Pulse chemisorption modeYes

 

SpaciMS

A system for determination of intra catalyst reactor chemistry

Measures the real-time concentration of gases inside a catalyst monolith
SpaciMS

Mass range

200 or 300 amu

Minimum detectable concentration

100 ppb

Maximum detectable concentration

100 %

Sample inlet pressure

100 mbar to 2 bar abs

Sampling inlet

Heated flexible silica

capillary

Fast measurement speed

Up to 500 measurments

per second

Number of inlets

Up to 16 (depending on

sample size)

Number of Thermocouples

Up to 16 (depending o

n sample size)

Sample flow required

Options for < 1 atm cc/min

to 20 atm cc/min

Corrosive gas sampling options

Yes

 

TPD Workstation

A system for UHV temperature programmed desorption (TPD/TDS) studies

Measures the desorption products from thin films and solid samples
TPD Workstation

Mass range

50, 200, 300 or 510 amu

Mass Spectrometer

Triple Filter Quadrupole

Detector

Pulse Ion Counter (PIC)

Sample size

Typically 10 x 10 mm

Minimum detectable pressure

5 x 10-15 mbar

Maximum operating pressure

5 x 10- 6 mbar

Maximum sample stage temperature

1000 °C

Fast measurement speed

Up to 500 measurements

per second

 

HPR-20 QIC TMS

A specialist gas analysis system for fast event transient analysis

Measures the concentration of fast event gases and vapours in real time
HPR-20 QIC TMS

Mass range

200 or 300 amu

Minimum detectable concentration

5 ppm

Maximum detectable concentration

100 %

Sample inlet pressure (Standard)

100 mbar to 2 bar abs

Response time to gas concentration

change

200 milliseconds (5 decades)

Fast measurement speed

Up to 500 measurements

per second (7 decades)

Sample flow required

Options for < 1 atm cc/min

to 20 atm cc/min

Corrosive gas sampling options 

Yes

 

TGA-MS

MS inlets for coupling to TGA systems

Measures the decoposition and desorption gases and vapours in real time from thermal analysis systems
TGA-MS

Mass range

200 or 300 amu

Minimum detectable concentration

100 ppb

Maximum detectable concentration

100 %

Sample inlet pressure

100 mbar to 2 bar abs

Sampling inlet

Heated flexible silica capillary

Response time to gas concentration

change

300 milliseconds

Fast measurement speed

Up to 500 measurments

per second

Sample flow required

Options for < 1 atm cc/min

to 20 atm cc/min

Corrosive gas sampling options 

Yes

 

3F-PIC

Components for UHV TPD (TDS) experiments

Measures the concentration of gases and vapours in real time
UHV TPD

Mass range

200, 300 or 510 amu

Range of Shrouds

Liquid N2 or Water Cooled,

Stainless steel or quartz

Temperature control

Options to control Eurotherm

PID units (RS485)

Detector

Pulse Ion Counter

Fast measurement speed

Up to 500 measurements per

second

Corrosive gas sampling options 

Yes

 

HPR-60 MBMS

A system for analysis of neutrals, radicals and ions

Measures the concentration of gases and vapours in real time
HPR-60 MBMS

Mass range

300, 510 or 1000 amu

Atmospheric plasma analysis

+ve and -ve ions and neutrals

Flame ionisation/combustion studies

+ve and -ve ions and neutrals

Neutral radical analysis

Appearance potential - APSI-MS

Electron attachment - EA-MS

Sample inlet pressure (standard)

                                        (optional)

atmospheric pressure

20 mbar, 100 mbar and 5 bar

 Fast measurement speed Up to 500 measurements per second

 

 

Contact us for more informations  

 Επιστροφή
Κεντρικά: Σταματίου Ψάλτου 30, 54644 Θεσσαλονίκη, Τηλ.: (+30) 2310-855844, Φαξ: (+30) 2310-886206
Υποκατάστημα: Μομφεράτου 131, 11475 Αθήνα, Τηλ.: (+30) 210-6452848, Φαξ: (+30) 210-6452413, www.megalab.gr, contact@megalab.gr

Created Alpha