Mass Spectrometers for Gas Analysis

 Real time gas analysers that address the broadest application range
Gas analysis products

QGA

Quantitative gas analyser

HPR-20 QIC R&D

Specialist gas analysis system for

advanced research

HPR-20 QIC R&D Plus

System with integrated gas control

calibration unit

HPR-20 QIC EGA

Gas analysis system for evolved

gas analysis in TGA-MS

TGA-MS

Mass spectrometer inlets for

connecting/coupling to TGA systems

HPR-20 QIC TMS

Transient mass spectrometer for fast

event gas analysis

QIC Biostream

Multi-stream gas/vapour analyser for

fermentation off-gas analysis

HPR-40 DSA

Membrane inlet mass spectrometer

for dissolved species analysis

HPR-60 MBMS

Molecular beam sampling mass

spectrometer for ion and radical analysis

HPR-70

Batch inlet gas analysis system for

discrete low volume sample analysis

HPR-90

Automated package cracking analysis

system for light bulb gas analysis

 

 

Contact us for more informations  

Mass Spectrometers for Gas Analysis

 

QGA

A compact bench-top system for real time gas and vapour analysis

Measures the concentration of gases and vapours in real time
QGA

Mass range

200 or 300 amu

Minimum detectable

concentration

100 PPB

Maximum detectable

concentration

100%

Sample inlet pressure

100 mbar to 2 bar abs

Sampling inlet

Heated flexible silica capillary

Standard capillary length

2 meters

Response time to gas

concentration change

300 milliseconds

Fast measurement speed

Up to 500 measurements

per second

Sample flow required (Standard)

16 atm cc/min

Sample flow required (Optional)

< 1 atm cc/min

to > 20 atm cc/min

Corrosive gas sampling options

Yes

 

HPR-20 QIC R&D

A specialist gas analysis system for advanced research

Measures the concentration of gases and vapours in real time
HPR-20 QIC R and D

Mass range

200, 300 or 510 amu

Minimum detectable

concentration

5 PPB

Maximum detectable

concentration

100%

Sampling inlet

Heated flexible silica

capillary

Standard capillary length

2 meters

Sample inlet pressure

(Standard)

100 mbar to 2 bar abs

Sample inlet pressure

(Optional) 

Up to 30 Bar

Response time to gas

concentration change

300 milliseconds

Fast measurement speed

Up to 500 measurements

per second

Sample flow required

(Standard)

16 atm cc/min

Sample flow required

(Optional)

< 1 atm cc/min

to > 20 atm cc/min

Corrosive gas sampling

options

Yes

 

HPR-20 QIC R&DPlus 

A real-time gas analyser with integrated gas control unit

Measures the concentration of gases and vapours in real time
HPR-20 QIC R and D Plus

Mass range

200, 300 or 510 amu

Gas control channels

4

Calibration and mixing

unit

Yes

Mass flow controllers

4

Minimum detectable

concentration

5 PPB

Maximum detectable

concentration

100%

Sample inlet pressure

(Standard)

100 mbar to 2 bar abs

Sample inlet pressure

(Optional) 

up to 30 Bar

Response time to gas

concentration change

300 milliseconds

Fast measurement speed

Up to 500 measurements

per second

Sample flow required

(Standard)

16 atm cc/min

Sample flow required

(Optional) 

< 1 atm cc/min

to > 20 atm cc/min

Corrosive gas sampling

options

Yes

 

 

 

 

 

 

 

 

 

HPR-20 QIC EGA

A compact bench-top system for evolved gas analysis in TGA-MS

Measures evolved gases and vapours from thermo gravimetric analysers (TGA)
HPR-20 QIC EGA

Mass range

200 or 300 amu

Minimum detectable

concentration

100 PPB

Response time to gas

concentration change

300 milliseconds

High capacity vacuum

pumping

Yes

Sample inlet

Heated flexible silica

capillary

Standard capillary length

2 meters

TA-MS adaptors/interfaces

to suit most TGA systems

Yes

Carrier gas 

Helium or Argon

Sample flow required

(Standard)

16 atm cc/min

Sample flow required

(Optional)

Options for < 1 atm cc/min

to > 20 atm cc/min

Fast measurement speed 

Up to 500 measurements

per second

Dedicated evolved gas

analysis software

Yes

Designed for TGA-MS

Yes

 

HPR-20 QIC TMS

A specialist gas analysis system for fast event transient analysis

Measures the concentration of gases and vapours from low PPM to high % levels in < 0.2 seconds.
HPR-20 QIC TMS

Mass range

200 or 300 amu

Minimum detectable

concentration

5 PPB

Maximum detectable

concentration

100%

Sample inlet

Heated flexible silica capillary

Standard capillary length

0.9 meters

Sample inlet pressure

100 mbar to 2 bar abs

Digital pulse ion counting

detector 

7 decade continuous log scale

Response time to gas

concentration change

150 milliseconds

Response time to 5 decade

change

< 200 ms

Fast measurement speed

Up to 500 measurements

per second 

Sample flow required

(Standard)

16 atm cc/min

Sample flow required

(Optional)

Options for < 1 atm cc/min

to > 20 atm cc/min

Corrosive gas sampling

options

Yes

 

QIC Biostream

An integrated mass spectrometer system for multi-stream fermentation off gas analysis

Measures off gas and vapour concentrations, OUR, CER, RQ  from multiple reactors
QIC Biostream

Mass range

200 or 300 amu

High flow options for

reactors > 1L

Yes

Low flow options for micro

reactors

Yes

Stream selection on the fly 

Yes

OPC connectivity

Yes

Number of streams

20, 40 or 80

Measures

O2, CO2, N2, C2H6O, CH4O

and other gases/vapours

OUR/CER/RQ (Method 1)

Includes flow rate

measurement

OUR/CER/RQ (Method 2)

Uses ratio, without

measured flow

Mass flow meter option

Stream flow rate measured

Mass flow meters

Single or dual

Mass flow meter ranges 

0-500 atm cc/min and

0 -12 atm litres/min 

Sample flow required (Low flow)

< 4 atm. cc/min

Sample flow required (High flow)

> 50 atm. cc/min

 

HPR-40 DSA - MIMS

A bench-top membrane inlet mass spectrometer designed for analysis of gases, vapours and VOCs in liquids

Measures dissolved gases in liquids, sea water, estuary, soil core and headspace.
HPR-40 DSA

Mass range

200 or 300 amu

Membrane enhanced

sensitivity

Yes

Sensitivity

~ 1 nmol/litre

Probe types for a broad range

of applications

Yes

Circular carrier

For flowing sample

Cuvette option

For microbiological

enzyme activity studies

Membrane inlet

Single or multiple inlet options,

4 or 8 way

 

 

 

 

 

 

 

HPR-60 MBMS

A molecular beam sampling mass spectrometer for analysis of neutrals, radicals and ions

Measures the reaction kinetics of processes at atmospheric pressure, 5 bar option.
HPR-60 MBMS

Mass range

300, 510 or 1000 amu

Atmospheric plasma analysis

+ve and -ve ions and neutrals

Flame ionisation/combustion

studies

+ve and -ve ions and neutrals

Neutral radical analysis

Appearance potential -

APSI- MS

Neutral radical analysis

Electron attachment-E A- MS

Sample inlet pressure (Standard)

Atmospheric pressure

Sample inlet pressure (Optional) 

20 mbar, 100 mbar and 5 bar 

Energy range options

100 or 1000eV

Application for High

Temperature Processes

 > 1000oC

Corrosive gas sampling options 

Yes

 

 

 

 

 

 

 

 

 

HPR-70

for Discrete Low Volume Sample Analysis

Measures the concentration of gases and vapours of  low volume samples.
HPR-70

Mass range

200, 300 or 510 amu

Minimum detectable concentration

5 PPB

Maximum detectable concentration

100%

Minimum sample volume

0.2 atm cm3  

Automatic dosing, expansion

Yes

Accurate sampling system

Yes

Corrosive gas sampling options

Yes 

 

 

 

 

 

HPR-90

A sealed package gas analyser with integral package cracker for lamp gas analysis

Measures the concentration of gases and vapours in hermetically sealed packages
HPR-90

Mass range

200, 300 or 510 amu

Minimum detectable concentration

5 PPB

Maximum detectable concentration

100%

Automated inlet

Accommodates a wide

range of sample sizes

Automatic data reporting

Yes

 

 

 

 

 

 

 

 

 

 