HPR-20 QIC R&D
Specialist gas analysis system for
advanced research
HPR-20 QIC R&D Plus
System with integrated gas control
calibration unit
HPR-20 QIC EGA
Gas analysis system for evolved
gas analysis in TGA-MS
TGA-MS
Mass spectrometer inlets for
connecting/coupling to TGA systems
HPR-20 QIC TMS
Transient mass spectrometer for fast
event gas analysis
QIC Biostream
Multi-stream gas/vapour analyser for
fermentation off-gas analysis
HPR-40 DSA
Membrane inlet mass spectrometer
for dissolved species analysis
HPR-60 MBMS
Molecular beam sampling mass
spectrometer for ion and radical analysis
HPR-70
Batch inlet gas analysis system for
discrete low volume sample analysis
HPR-90
Automated package cracking analysis
system for light bulb gas analysis
Contact us for more informations
Mass range
200 or 300 amu
Minimum detectable
concentration
100 PPB
Maximum detectable
100%
Sample inlet pressure
100 mbar to 2 bar abs
Sampling inlet
Heated flexible silica capillary
Standard capillary length
2 meters
Response time to gas
concentration change
300 milliseconds
Fast measurement speed
Up to 500 measurements
per second
Sample flow required (Standard)
16 atm cc/min
Sample flow required (Optional)
< 1 atm cc/min
to > 20 atm cc/min
Corrosive gas sampling options
Yes
200, 300 or 510 amu
5 PPB
Heated flexible silica
capillary
(Standard)
(Optional)
Up to 30 Bar
Sample flow required
Corrosive gas sampling
options
Gas control channels
4
Calibration and mixing
unit
Mass flow controllers
up to 30 Bar
High capacity vacuum
pumping
Sample inlet
TA-MS adaptors/interfaces
to suit most TGA systems
Carrier gas
Helium or Argon
Options for < 1 atm cc/min
Dedicated evolved gas
analysis software
Designed for TGA-MS
0.9 meters
Digital pulse ion counting
detector
7 decade continuous log scale
150 milliseconds
Response time to 5 decade
change
< 200 ms
High flow options for
reactors > 1L
Low flow options for micro
reactors
Stream selection on the fly
OPC connectivity
Number of streams
20, 40 or 80
Measures
O2, CO2, N2, C2H6O, CH4O
and other gases/vapours
OUR/CER/RQ (Method 1)
Includes flow rate
measurement
OUR/CER/RQ (Method 2)
Uses ratio, without
measured flow
Mass flow meter option
Stream flow rate measured
Mass flow meters
Single or dual
Mass flow meter ranges
0-500 atm cc/min and
0 -12 atm litres/min
Sample flow required (Low flow)
< 4 atm. cc/min
Sample flow required (High flow)
> 50 atm. cc/min
Membrane enhanced
sensitivity
Sensitivity
~ 1 nmol/litre
Probe types for a broad range
of applications
Circular carrier
For flowing sample
Cuvette option
For microbiological
enzyme activity studies
Membrane inlet
Single or multiple inlet options,
4 or 8 way
300, 510 or 1000 amu
Atmospheric plasma analysis
+ve and -ve ions and neutrals
Flame ionisation/combustion
studies
Neutral radical analysis
Appearance potential -
APSI- MS
Electron attachment-E A- MS
Sample inlet pressure (Standard)
Atmospheric pressure
Sample inlet pressure (Optional)
20 mbar, 100 mbar and 5 bar
Energy range options
100 or 1000eV
Application for High
Temperature Processes
> 1000oC
Minimum detectable concentration
Maximum detectable concentration
Minimum sample volume
0.2 atm cm3
Automatic dosing, expansion
Accurate sampling system
Automated inlet
Accommodates a wide
range of sample sizes
Automatic data reporting